Agilent Technologies 6287 Printer Accessories User Manual


 
6287 ULTRA Users ManualPage 9-2
After the users selections are keyed on the screen, press the local copy key
on the terminal. The ULTRA will interpret each command and store the
new selections in its non-volatile, battery-backed RAM. This is a form of
permanent storage that will hold the selections even when the unit is
powered off.
The command sequences will not be printed. They will affect only the
configuration of the ULTRA.
Multiple Option Selections
The user can change the parameters of more than one option in a single
line. Only one terminator per line is necessary to download option values.
To download several option parameters on a single line, the user must
separate each sequence with a comma (,) after each valid option parameter
value.
The following example illustrates multiple command selection, where
Trigger 1 is the default cent sign (¢). It sets the column width (Option#1) to
80, turns off local copy null line suppression (Option #4) and sets output
(Option #10) to EBCDIC mode:
¢?1=80,4=N,10=B;
Multiple lines may be used to download configuration option parameters.
Each line must have its own trigger and its own terminator.
Resetting All Options to Factory Defaults
To reset all options to factory preset default values, send the following
command to the ULTRA:
¢?0;
where the cent sign (¢) is Trigger 1 (the default).
Note: This command will reset all General Configuration options, all
programmable function strings and all translate tables to their factory