Page 5-13CONFIGURATION OPTIONS
55  MD-Laser Support
Determines whether or not the ULTRA will provide Maersk Data Products
continuous escape support. Select Yes if using Maersk Data software. If
this option is set to Yes, when the three-character sequence Esc C 2 is
detected in the data stream, the hexadecimal value of the character pairs
following the sequence will be sent to the printer until a terminator (Esc) is
detected. The default value is No. Refer to Section 11  Transparency
Modes for more information.
Note: If this option is set to Yes, Option #1  Column width should be
set to 0 (infinite line length), Option #2  Lines Per Page should be set to 0
(infinite page length), and Option #15  Bold Print Emulation should be
set to C (none). Otherwise, unpredictable formatting errors could occur.
Refer to Section 12  DisplayWrite 370 Support for more information.
56  Reserved
This option is reserved.
57  DSC NL at EM Even If in Column 1
IBM specifications state that the EM (End of Message) character will have
the effect of sending a CR/LF to the printer when the printhead is in any
column other than column one. Setting this option to No causes the
ULTRA to conform to this IBM specification, while setting it to Yes
causes a CR/LF to be sent to the printer whenever an EM is received,
regardless of the printhead position. The default value is No. Refer to
Section 15  DSC Data Streams for more information.
58  Metacode Support
Metacode is a variation of 35 Hex transparency. If this option is set to
Yes, Metacode support is enabled. If set to No, 35h will be ignored.
The default value is No. Refer to Section 11  Transparency Modes and
Section 16  Xerox Applications for more information.
Note: If this option is set to Yes, Option #1  Column width should be
set to 0 (infinite line length), Option #2  Lines Per Page should be set to 0
(infinite page length), and Option #15  Bold Print Emulation should be
set to C (none). Otherwise, unpredictable formatting errors could occur.