AMX NXA-ENET24 Switch User Manual


 
Introduction
8
NXA-ENET24 - Software Management Guide
System Defaults
The switch’s system defaults are provided in the configuration file “Factory_Default_Config.cfg.” To reset the
switch defaults, this file should be set as the startup configuration file (See Downloading System Software
from a Server section on page 34.) The following table lists some of the basic system defaults.
System Defaults
Function Parameter Default
Console Port Connection Baud Rate 9600
Data bits 8
Stop bits 1
Parity none
Local Console Timeout 0 (disabled)
Authentication Privileged Exec Level Username “Admin”
Password “1988”
Normal Exec Level Username “guest”
Password “guest”
Enable Privileged Exec from Nor-
mal Exec Level
Password “super”
RADIUS Authentication Disabled
TACACS Authentication Disabled
802.1x Port Authentication Disabled
HTTPS Enabled
SSH Enabled
Port Security Disabled
IP Filtering Disabled
Web Management HTTP Server Enabled
HTTP Port Number 80
HTTP Secure Server Enabled
HTTP Secure Port Number 443
SNMP SNMP Agent Enabled
Community Strings “public” (read only)
“private” (read/write)
Traps Authentication traps: enabled
Link-up-down events: enabled
SNMP V3 View: defaultview
Group: public (read only)
private (read/write)