Canon REALiS WUX6000 D Projector User Manual


 
207
Troubleshooting
Appendix Other Information
You Cannot Project an Image Appropriately
The Projector Power Turns Off
Cause Countermeasure
The projected image is
inverted in the vertical or
horizontal direction.
The ceiling mounted / rear projection setting is
incorrect. Check the [Image flip H/V] setting in the
[Install settings] menu. (P141)
The dot clock of the input
signal is higher than 162
MHz with a BNC cable.
Set the signal dot clock to 162 MHz or less on your
computer.
A computer cable is
used in which some pins
are not connected.
Use a computer cable in which all pins are
connected.
Cause Countermeasure
The air intake or exhaust
vent is blocked.
Check whether the air intake or exhaust vent is
blocked. If the air intake or exhaust vent is blocked,
the temperature inside the projector will increase and
the power is automatically turned off to protect the
projector. (The [WARNING] indicator and [TEMP]
indicator are lit.) Wait until the projector temperature
drops, then make sure that the intake and exhaust
vents are not blocked and turn on the projector. (P31,
P38)
The air filter is dirty. Check whether the air filter is clogged with dust.
If the air filter is clogged, clean or replace the air filter.
(P196)
The lamp has broken
(or there is a lamp
malfunction).
If the lamp has broken, follow the instructions on
“Precautions on the lamp” (P21).
The operating
temperature is
inappropriate.
Check whether the operating temperature is between
0°C (32°F) and 40°C (104°F). (P24)
Projector settings must be adjusted when using the
projector at altitudes of 2,300 m (7,545.8') or higher.
In the [Install settings] menu, set [Fan mode] under
[Professional settings] to [High altitude]. (P146)