Cisco ASR 1001-X Router Power Supplies
Figure 2-1 Cisco ASR 1001-X Router DC Power Supply and AC Power Supply
Cisco ASR 1001-X Power Supply Fans
The fans in the power supply module of the Cisco ASR 1001-X Router are used for cooling the power
supply module itself while system-level cooling is provided by four fans within the chassis. The power
supplies do not depend on the system-level fans for cooling. Fan failure is determined by fan-rotation
sensors.
Note The fans in the power supply modules will run as soon as the power supply is plugged in, even if the
Standby switch is in the Standby position.
Cisco ASR 1001-X Router AC Power Supply
The Cisco ASR 1001-X Router has two AC power supplies in the rear of the chassis. The input receptacle
is an IEC60320 C14 type of filtered AC inlet. The current rating on the connector is 10 A. Figure 2-2
shows the Cisco ASR 1001-X Router AC power supply.
371140