Cisco Systems ASR 1001-X Network Router User Manual


 
5-17
Cisco ASR 1001-X Router Hardware Installation Guide
OL-32376-02
Chapter 5 Cisco ASR 1001-X Router Power Up and Initial Configuration
Environmental Monitoring and Reporting Functions
AC Input Range: 85 to 264 VAC
In addition, the power supplies monitor internal power supply temperatures and voltages. A power
supply is either within tolerance (normal) or out of tolerance (critical). If an internal power supply
temperature or voltage reaches a critical level, the power supply shuts down without any interaction with
the system processor.
The environmental monitoring functions use the following levels of status conditions to monitor the
system:
Normal—All monitored parameters are within normal tolerances.
Warning—The system has exceeded a specified threshold. The system continues to operate, but
operator action is recommended to bring the system back to a normal state.
Critical—An out-of-tolerance temperature or voltage condition exists. The system continues to
operate, but the system is approaching shutdown. Immediate operator action is required.
Shutdown—Before any shutdown, the system logs the status of monitored parameters in NVRAM
so that you can retrieve it later to help determine the cause of the problem.
Power supply shutdown—The power supply detected an internal out-of-tolerance overvoltage,
overcurrent, or temperature condition and shut itself down. All DC power remains disabled until you
toggle the power switch.
Note The Cisco ASR 1001-X Router does not shut down automatically during an over-temperature condition.
The router will remain active irrespective of what the ambient temperature is, if the router is exposed to
an extremely hot environment for a prolonged period of time, it will remain active until the hardware
fails.
The facility-alarm critical exceed-action shutdown command is disabled on the Cisco ASR 1001-X
Router.
The console terminal displays the following error message if you execute the facility-alarm critical
exceed-action shutdown command:
Router(config)# facility-alarm critical exceed-action shutdown
Router(config)# end
Router#
*Apr 22 15:27:26.939: %CMANRPCHAIN-6-NOSHUTWARN: Shutdown not supported on this platform
*Apr 22 15:27:27.974: %SYS-5-CONFIG_I: Configured from console by console
Router#
If the air temperature exceeds a defined threshold, the system controller displays the following warning
message on the console terminal:
Router#
*Apr 22 15:30:37.749: %CMRP_ENVMON-3-TEMP_WARN_CRITICAL: R0/0: cmand: WARNING: Temp:
Inlet temperature sensor on R0 is in a critical state reading 81
Router#
The console terminal displays the following status if you execute the show facility-alarm status
command:
Router# show facility-alarm status
System Totals Critical: 2 Major: 0 Minor: 0
Source Time Severity Description [Index]