HP (Hewlett-Packard) 2520 Switch User Manual


 
Time Protocols
SNTP: Viewing, Selecting, and Configuring
==========================- CONSOLE - MANAGER MODE -========================
Switch Configuration - System Information
System Name : ProCurve
System Contact :
System Location :
Inactivity Timeout (min) [0] : 0 MAC Age Time (sec) [300] : 300
Inbound Telnet Enabled [Yes] : Yes Web Agent Enabled [Yes] : Yes
Time Sync Method [None] : TIMEP
TimeP Mode [Disabled] : Disabled
Tftp-enable [Yes] : Yes
Time Zone [0] : 0
Daylight Time Rule [None] : None
Time Protocol Selection Parameter
–TIMEP
–SNTP
–None
Actions-> Cancel Edit Save Help
Figure 9-1. The System Information Screen (Default Values)
2. Press [E] (for E
dit). The cursor moves to the System Name field.
3. Use [v] to move the cursor to the Time Sync Method field.
4. Use the Space bar to select SNTP, then press [v] once to display and move
to the SNTP Mode field.
5. Do one of the following:
Use the Space bar to select the Broadcast mode, then press
[v] to
move the cursor to the Poll Interval field, and go to step 6. (For
Broadcast mode details, refer to “SNTP Operating Modes” on
page 9-2.)
Time Sync Method [None] : SNTP
SNTP Mode [Disabled] : Broadcast
Poll Interval (sec) [720] : 720
Tftp-enable [Yes] : Yes
Time Zone [0] : 0
Daylight Time Rule [None] : None
Figure 9-2. Time Configuration Fields for SNTP with Broadcast Mode
Use the Space bar to select the Unicast mode, then do the
following:
i. Press
[>] to move the cursor to the Server Address field.
ii. Enter the IP address of the SNTP server you want the switch to
use for time synchronization.
9-6