Configuring for Network Management Applications
Using SNMP Tools To Manage the Switch
Note The retries and timeout values are not used to send trap requests.
To verify the configuration of SNMPv2c informs, enter the show snmp-server
command:
ProCurve(config)# show snmp-server
SNMP Communities
Community Name MIB View Write Access
---------------- -------- ------------
public Manager Unrestricted
Trap Receivers
Link-Change Traps Enabled on Ports [All] : All
...
Address Community Events Sent Notify Type Retry Timeout
--------------------- --------------- ----------- ----------- ----- --------
15.28.333.456 guest All inform
SNMPv2c Inform
configuration
3 15
Excluded MIBs
Snmp Response Pdu Source-IP Information
Selection Policy : Default rfc1517
Trap Pdu Source-IP Information
Selection Policy : Configured IP
Ip Address : 10.10.10.10
Figure 13-9. Display of SNMPv2c Inform Configuration
13-22