Switch Manager
104 HP StorageWorks 2/8q Fibre Channel Switch Management User Guide
Load Firmware dialog box messages
Port Loopback Test dialog box messages
Table 34: Load Firmware dialog box messages
Message User action
Bad checksum/CRC for the firmware image or
incorrect firmware image for this type of
switch.
Select the correct firmware file for this switch.
File was not found. Verify that the firmware file specified actually
exists, or specify a new firmware file.
Firmware image had a bad CRC or was
invalid for this type of switch.
Select a valid firmware image for this type of
switch and retry the operation.
Firmware upload status unknown. Image has
been uploaded, but confirmation from the
switch was not received.
The application lost communications with the
switch while the switch was unpacking the
firmware image. If the problem was
temporary, examine the firmware versions on
the switch to verify that the firmware was
unpacked correctly, or upload a new firmware
image to the switch.
The flash memory on the switch may be too
small for this image.
Select an appropriate firmware image for this
type of switch and retry the operation.
Unable to load firmware. An unspecified error has occurred. Verify that
the user has permissions to modify the
configuration on the switch, that the switch is
reachable in the fabric, and that the fabric is
reachable from the user’s workstation, and
then retry the firmware upload.
Unable to read file. Verify that the firmware file specified exists
and is readable by the user, on a file system
readable by the user, or specify a new
firmware file.
Table 35: Port Loopback test dialog box messages
Message User action
Attempt to put port in diagnostic state has
failed. Unable to continue with port test.
Verify that the user has permissions to modify
the configuration on the switch, that the switch
is reachable in the fabric, and that the fabric is
reachable from the user’s workstation, and
then retry the configuration change.
External port test requires a loopback device
be plugged into the selected port. Click “OK”
when loopback device is installed.
Verify that a loopback device is attached to the
port before starting loopback test.
Failed to correctly restore port states for one or
more ports.
Return to the faceplate view and then select
View>Port State to determine which port was
not restored to its original state. Select the
port, and then select Port>Port Properties to
restore the port state.
Invalid frame count value.
or
Invalid frame size. Must be 36 to 2148.
or
Invalid hex pattern. Up to 8 hex digits
allowed.
Verify that all information is valid, and then
retry the loopback test.