HP (Hewlett-Packard) 2/8q Fibre Channel Switch User Manual


 
Switch Manager
107HP StorageWorks 2/8q Fibre Channel Switch Management User Guide
No response from the switch.
or
Saving zoning data failed.
Verify that the user has permissions to modify
the configuration on the switch, that the switch
is reachable in the fabric, and that the fabric is
reachable from the user’s workstation, and
then refresh the zoning information from the
switch to determine whether any of the zoning
configuration has been applied. If necessary,
re-edit the zoning configuration and apply to
the switch again.
The maximum number of members has been
reached.
or
The maximum number of members per zone
has been reached
Remove unnecessary objects from the zoning
configuration and retry the operation.
The Orphan set is a place a holder for zones
that are not in a set. It can not be deleted.
Do not attempt to delete the orphan zone set.
The zone set you are attempting to activate
contains port based zoning and there are
switches in the fabric that might not support
this type of zoning. Some E_Ports may isolate.
Do you wish to continue?
Not all switch vendors support port-based
zoning. Consult the manual for these vendors’
switches to determine whether to apply this
zoning configuration to the fabric. This feature
is not supported by HP.
The zoning configuration has been changed.
Would you like to apply your changes?
The zoning configuration includes changes
that have not been applied to the switch. Click
Yes to apply the changes to the switch before
continuing, or click No to discard the changes
and continue.
There is already a zone by that name in a
different Zone set. Would you like to add that
zone to this Zone Set?
If the existing zone is the same as zone that the
user wants to add to this zoneset, continue.
Otherwise, select a unique name for the new
zone, and then retry the operation.
There is already a zone set with that name.
or
There is already a zone with that name.
or
There is already a alias with that name.
Select a unique name for the new object, and
then retry the operation.
This zoning configuration exceeds the limits for
this switch.
Remove unnecessary objects from the zoning
configuration, and then retry the operation.
Table 37: Zoning dialog box messages (Continued)
Message User action