HP (Hewlett-Packard) 2/8q Fibre Channel Switch User Manual


 
Switch Manager
67HP StorageWorks 2/8q Fibre Channel Switch Management User Guide
Figure 25: Port Threshold Alarm example
7. Enter a sample window in seconds.
The sample window defines the period of time in which to count events.
8. Repeat step 3 through step 7 for each alarm you want to configure or enable.
9. Click OK.
Exporting name server information to a file
To save name server information to a file, open the topology display and do the following:
1. Select one or more switches. If no switches are selected, name server information is
gathered for all switches.
2. Select Switch > Export Name Server. The Save dialog box is displayed.
3. Enter a file name in the Save dialog box.
4. Click Save.
Paging a switch
You can use the beacon feature to page a switch. The beacon feature causes all Logged-In
LEDs to flash, making it easier to recognize.
To page a switch, select Switch > Toggle Beacon.
To cancel the beacon, reselect Toggle Beacon.
Rising
Trigger
Falling
Trigger
Event
Count
Sample Window
Generate falling
trigger alarm;
eligibility is reset
Generate rising
trigger alarm;
eligibility ends
Generate rising
trigger alarm;
eligibility ends