HP (Hewlett-Packard) 2/8q Fibre Channel Switch User Manual


 
Command Line Interface
145HP StorageWorks 2/8q Fibre Channel Switch Management User Guide
PORT—Monitors all port events.
SNMP—Monitors SNMP events.
SWITCH—Monitors switch management events.
ZONING—Monitors zoning conflict events.
ALL—Monitors all components.
NONE—Monitor none of the component events.
DISPLAY [filter]
Specifies the log events to automatically display on the screen according to the event
severity levels given by [filter]. [filter] can be one of the following values:
CRITICAL—Critical severity level events. The critical level describes events that are
generally disruptive to the administration or operation of the fabric, but require no
action.
WARN—Warning severity level events. The warning level describes events that are
generally not disruptive to the administration or operation of the fabric, but are more
important than the informative level events.
INFO—Informative severity level events. The informative level describes routine
events associated with a normal fabric.
NONE—Specifies no severity levels for display on the screen.
LEVEL [filter]
Specifies the severity level given by [filter] to use in monitoring and logging events
for the specified components or ports. [filter] can be one of the following values:
CRITICAL—Monitors critical events. The critical level describes events that are
generally disruptive to the administration or operation of the fabric, but require no
action.
WARN—Monitors warning and critical events. The warning level describes events that
are generally not disruptive to the administration or operation of the fabric, but are
more important than the informative level events.
INFO—Monitors informative, warning, and critical events. The informative level
describes routine events associated with a normal fabric. This is the default severity
level.
NONE—Monitors none of the severity levels.
PORT [port_list]
Specifies one or more ports to monitor for events. Choose one of the following values:
[port_list]—Specifies port or ports to monitor. Use a <space> to delimit values in
the list. Ports are numbered beginning with 0.
ALL—Specifies all ports.
NONE—Disables monitoring on all ports.
RESTORE