Hitachi J300U Series Power Supply User Manual


 
7-23
Contents and display
Extension
function
code
Frequency
arrival
signal
output
method
1
2
FUNC
FUNC
Set value
Function
0
At the time of constant speed arrival
1 Optionally set frequency or more
Initial value
Setting method
When selecting the frequency arrival signal at the output terminal, select the arrival signal output
method.
Set optional frequencies of set value 1 and set
value 2 by and .
Initial
value
2
Only optionally set frequency
Output
frequency
(Hz)
0
ON
Time
At the time of constant
speed arrival
Output
frequency
(Hz)
Output
frequency
(Hz)
Arrival
signal
Arrival
signal
Arrival
signal
:
ON
Time
Optionally set frequency
or more
:
ON
Time
Only optionally set
frequency
:
Restarting
after FRS
signal
selection
1
2
FUNC
Setting method
Select an operation after a free run stop.
Set and with the and keys.
Set value Function
1
0
1
0
0
ON
NOTE 1: The frequency arrival signal
can be allocated only to one
of the intelligent output terminals.
It cannot be outputted to
an individual output terminal
for acceleration and deceleration.
0.5Hz
1.5Hz
setting
60 ms
0.5Hz
1.5Hzsetting setting
60 ms
0.5Hz
1.5Hz
setting
setting
60 ms
0.5Hz
1.5Hz
60 ms
f matching
0 start
2
NOTE 2: Selection of arrival signal output
method for relay option board (J-RY)
can be done by remote oprator and
F-48 funciton.
Initial value
Initial value