Hughes DW4020 Network Hardware User Manual


 
Chapter 2 • Installing the indoor equipment
1031484-0001 Revision 2
29
12. Select the Manual fine pointing mode radio button.
13. Select Start Test. Adjust the antenna to achieve maximum
transmit isolation.
14. When the unit consistently passes the manual transmit test,
bolt the antenna securely before going to Step 15.
15. After the antenna is bolted, select
Stop Test. See Figure 28.
16. Then select the
Automatic radio button and select Start Test
to start the automatic ACP test. See Figure 29.
17. Make sure the test passes.
18. Select Exit after passing the test.
Figure 28: Manual cross-pol passed; select Stop Test
Figure 29: Auto cross-pol