Lenovo TD100X Laptop User Manual


 
Installing a non-hot-swap power supply cage assembly (TD100 - some
models)
To install a non-hot-swap power supply, complete the following steps.
1. Align the screw holes in power supply cage pivot bracket with the corresponding
screw holes on the rear of the chassis.
Power supply
assembly
Power supply
retaining screws
2. While you support the power supply cage, install the three screws that secure
the power supply to the chassis.
3. Press the power-supply cage release tab and rotate the power-supply cage
assembly into the chassis until it locks in place.
4. Return the power-supply cage handle to the locked position.
5. Connect the cables from the power supply to the system board and all internal
components.
6. Install the side cover (see “Installing the side cover” on page 79).
7. Lock the side cover.
8. Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
Removing the hot-swap power supply docking cable assembly
To remove the hot-swap power supply docking cable assembly, complete the
following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 73.
2. Turn off the server and all attached devices; then, disconnect all power cords
and external cables.
3. Unlock and remove the side cover (see “Removing the side cover” on page 78).
Note: It might be helpful to lay the server on its side for the remainder of this
procedure.
4. Remove the power supply from the power supply cage.
Chapter 4. Removing and replacing server components 135