Lenovo TD100X Laptop User Manual


 
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code Description Action
035-292-001 Adapter Parameter Set Error.
1. Update the RAID controller firmware (see
“Updating the firmware” on page 15).
2. Reseat the RAID controller.
3. Replace the RAID controller.
075-xxx-000 Failed power supply test. Reseat the following components:
1. Hot-swap power supply.
2. Hot-swap power backplane.
3. Replace the following components (depending on
your model):
v Hot-swap power supply
v (Trained service technician only) Non-hot-swap
power supply
089-xxx-001 Failed microprocessor test.
1. Make sure that the BIOS code is at the latest
level.
2. (Trained service technician only) Reseat
microprocessor 1.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. (Trained service technician only)
Microprocessor 1
b. (Trained service technician only) System
board
089-xxx-002 Failed optional microprocessor test.
1. Make sure that the BIOS code is at the latest
level.
2. (Trained service technician only) Reseat
microprocessor 2.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. (Trained service technician only)
Microprocessor 2
b. (Trained service technician only) System
board
194 ThinkServer TD100 and TD100x: Hardware Maintenance Manual