2
CLI Commands
McDATA OPENconnectors Command Line Interface USER MANUAL P/N 620-000134-300
2-80
Reason An optional message number that indicates if
the port has a segmented ISL, if a port binding
violation has occurred, or if the port is inactive.
The message description for this message
number is provided at the bottom of the table.
If the operational state is Segmented E_Port, only
the following messages can be generated:
• 00 Segment Not Defined
• 01 Incompatible Operating Parameters
• 02 Duplicate Domain ID(s)
• 03 Incompatible Zoning Configurations
• 04 Build Fabric Protocol Error
• 05 No Principal Switch
• 06 No Response from Attached Switch
• 07 ELP Retransmission Failure Timeout
If the operational state is Invalid Attachment only
the following messages can be generated:
• 08 None
• 09 Unknown
• 10 ISL connection not allowed on this port
• 11 ELP rejected by the attached switch
• 12 Incompatible switch at other end of the ISL.
• 13 External loopback adapter connected to the
port
• 14 N_Port connection not allowed on this port
• 15 Non-McDATA switch at other end of the ISL.
• 16 ISL connection not allowed on this port
• 17 ISL connection not allowed to external Fabrics
• 18 Port binding violation—unauthorized WWN
• 19 Unresponsive node connected to port
• 20 Incompatible security attributes
• 21 Fabric Binding violation
• 22 Authorization failure
• 23 Switch Binding violation
If the operational state is Inactive only the
following messages can be generated:
• 24 Inactive – RC 0
• 25 No Serial Number
• 26 Feature Not Enabled