Error Messages
McDATA OPENconnectors Command Line Interface USER MANUAL P/N 620-000134-500
A-12
Message Error 89: Not Allowed in S/390 Mode Without the SANtegrity (TM)
Feature
Description Cannot configure port types in S/390 mode without installing
SANtegrity.
Action This command is only supported when the switch is in Open Systems
mode or in S/390 with SANtegrity. The switch will need to be taken
out of S/390 Mode in order to complete this command or SANtegrity
will need to be purchased and installed. The switch cannot be taken
out of S/390 Mode via the Command Line Interface. The EFC
Manager application must be used to change the switch operating
mode.
Message Error 90: Invalid Port Type
Description The port type configured is invalid.
Action A port may be configured to be an eport, gport, or fport. Be sure the
port is configured appropriately and re-submit the command.
Message Error 91: E_Port Type Configured
Description Ports are not allowed to be configured as E_Ports in S/390 mode.
Action Configure the port as either a fport or gport and resubmit the
command.
Message Error 92: Not Allowed While Port Is Unblocked
Description The port must be blocked to complete this request.
Action Block the port and re-submit the command.
Message Error 93: Not Allowed While FICON MS Is Installed
Description This request cannot be completed because FICON Management
Server is installed.
Action This operation is not supported. No action necessary.