Primera Technology RX300 S2 Server User Manual


 
153
PRIMERGY RX300 S2 User’s Guide
5
Operations after OS Installation
BIOS Setup Utility Setting
When power management is performed via a LAN, configure the settings as follows using the BIOS
Setup Utility. The power management via a LAN is set to "Enabled" by default.
1 Start the BIOS Setup Utility.
"8.2.1 Starting and Exiting the BIOS Setup Utility" (pg.223)
2 From the [Advanced] menu, select the [Power On/Off] submenu and press the
[Enter] key.
The [Power On/Off] submenu window appears.
3 Set [Power On Source: LAN] to [Enabled].
"8.2.9 Power On/Off Submenu" (pg.237)
To start up the server via a LAN, refer to " Performing Remote Installation" (pg.44).
5.5.6 Other Notes on Operation
Unnecessary Files
After OS installation is completed, folders named Runonce and Runonce 2 may be left in the drive
where the OS is installed. Delete these folders since you do not need them for the system operation.
Notes on 24-hour Operation
Automated System Operation
To provide an extra margin of safety against unintentional damage, introduce disaster-prevention
measures in the office and keep disaster prevention personnel (such as a security guard or janitor) in the
building.
Unintentional Power-off Prevention
We recommend the installation of a special power supply device (such as a distribution board) to prevent
unplanned power shut-offs.