Primera Technology RX300 S2 Server User Manual


 
238
Chapter 8 Hardware Configuration/Utilities
8.2.10 IPMI Submenu
Appears when [IPMI] is selected from the [Advanced] menu.
Configures the Baseboard Management Controller (BMC).
Wake Up Time - Configures the power-on time setting using the
timer.
Wake Up Mode - Specifies the power-on interval using the timer.
Power Failure Recovery Always Off
Always On
Previous State (at the
time of purchase)
Sets the server power status after system down due
to power failure or after power recovery by the
UPS.
Note:
Set this item to [Always ON] when a UPS is
used.
table: Items on the IPMI Submenu
Item Setting Description
SEL Load - Displays the stored SEL in percentage.
Clear System Event Log Disabled (at the time of
purchase)
Enabled
Deletes logs stored in System Event Log (SEL).
(Do not delete SEL from this menu.)
Event Log Full Mode Overwrite (at the time of
purchase)
Maintain
Configures the log when full SEL is indicated.
BMC Time Sync Enabled (Fixed parameter) Sets whether or not to synchronize the BMC
internal timer with RTC at startup.
table: Items on the Power On/Off Submenu
Item Setting Description
Item Specific Help
F1
Esc
Select Item
Select Menu
Change Values
Select Sub-Menu
-/+
Enter
Info
Exit
F9
F7
Setup Defaults
Previous Values
PhoenixBIOS Setup Utility
Advanced
SEL Load nn%
Clear System Event Log [Disabled]
Event Log Full Mode: [Overwrite]
BMC Time Sync: [Enabled]
System Event Log
SDRR Browser
LAN Settings
IPMI