Xantrex Technology XMP 2600 Power Supply User Manual


 
Power module setup Power Supply setup
Remember to set the LSN address to same value as the TLK address
by selecting it and pressing the ENTER key.
To end the GPIB setup mode, do one of the following:
Press the SET key.
Press the SYSTEM key. This will, also, move the cursor to the system
symbol.
Following power-on or a full reset the GPIB address and activation
state are restored from the dip switches located at the back of the
unit. For further details please refer to chapter 2: Installation.
Power module setup
In the setup mode you have access to additional power module parameters and
information.
What is
displayed
The following illustration shows a typical display of a power module setup.
Power module
location
Last known
error code
syste
m
symbol
syste
m
p
arameters to se
t
condense
d
modules status
Power module
ra
ting
Reprogramming
dela
y
Setup mode display – power module setup
How to get
there
To get to the power module setup proceed as follows:
Make sure the display is in setup mode.
Select the power module (move the cursor to the condensed status
symbol of the power module) using the LEFT / RIGHT selection keys.
Display
details
The information shown on the display during power module setup is summarized in
the table bellow:
Parameter Description
MAX
Power module rating: maximal available output voltage and
current.
DLY=
The amount of reprogramming delay (shown in units of 0.1
second). To understand what reprogramming delay is, please
refer to the section on setting the reprogramming delay.
86 XMP 2600 User’s Guide rev. 1.0