Xantrex Technology XMP 2600 Power Supply User Manual


 
Clearing faults Basic operation
Clearing faults
The XMP 2600 has two categories of faults: power module faults and power system
faults.
Clearing
power
module faults
To clear power module faults (e.g. OVP, OCP etc.), proceed as follows:
Select the power module with the fault, in status display mode.
Press the RESET key.
Clearing
power system
faults
To clear power system faults (e.g. module caused shutdown), proceed as follows:
Move the cursor to the system symbol, in status mode.
Press the RESET key.
Depending on the type of fault that you are trying to reset, the XMP 2600 main
controller may find it necessary to perform a full reset.
Power supply reset
To reset the entire power supply system, press and hold down the DEL key , then
(within 1 Second) while holding the DEL key pressed, press the LOCAL key - the
two keys must be pressed together.
This will reset the entire Power Supply, returning it to its power on state.
The front panel reset operation can be executed any time regardless of the operating
state the Power Supply is in.