Sequence programming Running the sequence program
Monitor
sequence
program
execution
While the sequence program is running the global system status display changes,
showing the sequence program progress of execution.
Step
numbe
r
Amount o
f
dela
y
lef
t
Operation to do
when dela
y
is ove
r
total outpu
t
p
owe
r
syste
m
symbol
system status
or instructions
condense
d
modules status
Global system status display during sequence program run mode
This modified global system status display is shown whenever the cursor is placed at
the system symbol, in status mode, during sequence program execution.
Control
sequence
program
execution
While the sequence program is running, you have some degree of control over its
execution.
To be able to control the execution of the sequence program you need the display to
show global system status (the modified version, showing sequence program
execution progress as explained above).
Shorten the current delay period
Press the ENTER key to shorten the delay period of the currently active step.
The delay is shortened to zero and the step carries out its operation.
Stop the sequence program
To abort execution of the sequence program, press the RESET key.
When execution of the sequence program ends, the XMP 2600
retains the last state set by the sequence program.
XMP 2600 User’s Guide