Xantrex Technology XMP 2600 Power Supply User Manual


 
Viewing status information Using the front panel
Parameter Displayed data (left to right)
LOAD
Output voltage as measured by the sense lines and load
current.
Operating mode: VM=voltage mode (operating as a
voltage source), CM=current mode (operating as a
current source), FB=foldback is active.
Foldback selection (see below).
Detailed module status (see below).
SET
Programmed output voltage and current limit (or voltage
limit and output current if operating as a current
source).
Operating mode: VM=voltage mode (operating as a
voltage source), CM=current mode (operating as a
current source), FB=foldback is active.
Foldback selection (see below).
Detailed module status (see below).
RIPL
Selection of simulated ripple at the module’s output: level
(OFF, LOW or HIGH) and frequency (50Hz,
60Hz, 100Hz, 120Hz, 400Hz, 800Hz, 2KHz).
Operating mode: VM=voltage mode (operating as a
voltage source), CM=current mode (operating as a
current source), FB=foldback is active.
Foldback selection (see below).
Detailed module status (see below).
PROT
Over voltage and over current protection threshold levels.
Protection levels programming method: AUT=automatic
(auto-tracking) or MAN=manual (user
programmed).
Detailed module status (see below).
MAX
Power module ratings: voltage and current.
Operating mode: VM=voltage mode (operating as a
voltage source), CM=current mode (operating as a
current source), FB=foldback is active.
Foldback selection (see below).
BIT=00,00 the power module, continuously, performs
built-in-tests with the results displayed as two
numbers. The equal sign flashes as each cycle of
BIT is performed.
LIM
Voltage and current values that serve as limits on the
allowed output values to program (SET
parameter).
Operating mode: VM=voltage mode (operating as a
voltage source), CM=current mode (operating as a
current source), FB=foldback is active.
Foldback selection (see below).
Detailed module status (see below).
32 XMP 2600 User’s Guide rev. 1.0