Xantrex Technology XMP 2600 Power Supply User Manual


 
Using the front panel Front panel description
The STO function key
The following table summarizes the functions of the STO function key:
Operating mode Cursor location Function
Module status Module symbol Initiate a STORE operation. Press
a digit (0 to 9) for the storage
number and confirm with
ENTER. Press DEL to cancel.
This operation stores the settings
of all
the modules.
Module programming
- SET parameters
Any ARM the Power Module. All new
PROTECTION and SET values
programmed for that Power
Module do not affect the output.
A subsequent hardware or
software trigger will cause the
Power Module to perform a
selected task.
System status System symbol Enter sequence program editing
Module Setup Module symbol Initiate manual calibration
The RCL function key
The following table summarizes the functions of the RCL function key:
Operating mode Cursor location Function
Module status Module symbol Initiate a RECALL operation.
Press a digit (0 to 9) for the
storage number and confirm with
ENTER. Press DEL to cancel.
This operation restores the
settings of all
the modules.
Module programming
- SET parameters
Any TRIGGER the Power Module,
causing it to perform a selected
task.
System status System symbol Run the sequence program
System Setup System symbol Displays the Mainframe
Controller’s firmware version
string on the upper row of the
display (the same string as can be
read remotely using the ROM?
Command).
Module Setup Module symbol Display Power Module’s Serial
Number, Calibration date,
Options and EVENT register.
Pressing RCL a second time
displays the Power Module’s
Revision and Date codes.
XMP 2600 User’s Guide