ADIC SNC 5100 Network Card User Manual


 
Commands 119
6-00020-02
SNC 5100
Air Outlet Temperature Nominal 51 C
IO Processor Temperature Warning 31 C
Input Power: ±5 Volts Nominal 5.2 V
Input Power: ±12 Volts Nominal 12 V
Local Power ±2.5 Volts Nominal 3.3 V
Local Power ±3.3 Volts Nominal 3.3 V
Local Power ±3.3 Volts Aux Nominal 3.29 V
All Power Nominal
All Temp Nominal
Sample Count 20
value=1=0x1
envMonRangeShow
The
envMonRangeShow command specifies operational ranges for the SNC
5100's environmental channels. It displays ranges of values associated with the
Nominal, Warning, and Alarm states for voltage, temperature, and fan/blower
operation according to the channels defined in the envMonShow command:
SN600012 > envMonRangeShow
Air Inlet Temp (C):
Nominal: 5 to 45
Warning: 4 <=N<5or45<N<=50
Alarm: N<4orN>50
Air Outlet Temp (C):
Nominal: 5 to 50
Warning: 4 <=N<5or50<N<=55
Alarm: N<4orN>55
IO Processor Temp (C):
Nominal: 5 to 80
Warning: 4 <=N<5or80<N<=108
Alarm: N<4orN>108