ADIC SNC 5100 Network Card User Manual


 
Commands 173
6-00020-02
SNC 5100
snmpReadCommunityAdd string” ,[view]
The snmpReadCommunityAdd command adds the specified string to the
list of accepted strings for SNMP Read operations (Get and GetNext). The
View switch must be set to 1 to be accepted by the ADIC Management
Console.
For more information, see the ADIC Management Console User Guide.
SN60023 > snmpReadCommunityAdd adic,1
Success
value=4=0x4
SN60023>
snmpReadCommunityRemove string
The snmpReadCommunityRemove command removes the specified string from
the list of accepted strings for SNMP Read operations.
SN60023 > snmpReadCommunityRemove adic
Success
value=3=0x3
SN60023 >
snmpTrapCommunitySet string”,[view]
The
snmpTrapCommunitySet command sets the community string passed
with all SNMP traps. The View switch must be set to 1 to be accepted by the
ADIC Management Console.
For more information, see the ADIC Management Console User Guide.
SN60023 > snmpTrapCommunitySet adic,1
Success
value=8=0x8
SN60023 >
snmpWriteCommunityAdd string”,[view]
The
snmpWriteCommunityAdd command adds the specified string to the list
of accepted strings for SNMP Write operations (Set). The View switch must be
set to 1 to be accepted by the ADIC Management Console.