ADIC SNC 5100 Network Card User Manual


 
Fibre Channel MAP 61
6-00020-02
SNC 5100
Step 3. Wait for the SNC 5100 to finish booting.
Step 4. If the SNC 5100 is in diagnostic mode (command prompt =
diagmode >), then restore normal operation.
For more information, see Restoring Normal Mode on page 188.
Step 5. Perform a health check.
For more information, see Perform Health Check on page 46.
Step 6. Review the host event log.
For more information, see Check the Host Event Log on page 47.
If all attached SCSI devices and cables are determined to be good,
yet SCSI errors persist, replace the SNC 5100.
Go to Before Removing or Replacing the Unit on page 82.
Proceed through Replacing the SNC 5100 on page 84.
Exit this MAP.
Fibre Channel MAP
Perform these steps if:
The Fibre Channel interface reports a reset or system error
The Fibre Channel interface reports an error processing a request or
response
The Fibre Channel interface reports an excess of 10 LIPs in a 10-minute
interval
Other Fibre Channel errors reported
FC connection LED is off
Verify Fibre Channel Connections
Step 1. Connect the service terminal to the Service Port.
For more information, see Connecting to the Service Port on
page 95.