ADIC SNC 5100 Network Card User Manual


 
SNC 5100
138 Commands
6-00020-02
hostNameSet
The hostNameSet command changes the network name of the SNC 5100.
The shell prompt will be set to the new host name.
SN60023 > hostNameSet "foster"
Target hostname set to foster
value=0=0x0
foster >
hostShow
The
hostShow command displays the IP address and alias (if any) of the unit
processing the
hostShow command, the localhost and the timeserver host.
SN600012 > hostShow
hostname inet address aliases
-------- ------------ -------
SN600012 192.168.1.172
localhost 127.0.0.1
host 192.168.1.127
value=0=0x0
SN600012 >
hostTypeShow
The
hostTypeShow command displays the host type setting for each Fibre
Channel. The possible host types are AIX, AS400, Gateway, FCR-2, HP-UX,
Linux, NT (includes Windows 2000), Netware, Generic, Solaris,
Autosense/NT, or Dell PV-136T-FC.
SN60023 > hostTypeShow
FC 1: Type 2 nt
FC 2: Type 1 solaris
value=0=0x0
SN60023 >
The output in the example could be the result of the users choosing either
Linux or Solaris for the host attached to FC2.
icmpstatShow
The
icmpstatShow command displays ICMP statistics for the Ethernet