sfmSparseAccessSet[hostindex],“LUN string”,[Access]
The
sfmSparseAccess command sets the access for the specified LUNs for
the specified host connection index. Same as
sfmAccessSet except LUNs
are entered as a string of characters separated by commas. Existing hostindex
values can be determined by looking at the “Id” column in the output of the
sfmShow -1 command.
When you enter this command, the settings are stored in memory but are not
applied until you enter the
sfmAccessApply command. The following
command example enables host access to the LUNs 1, 2, 3, 4, 6, 9, 22, 23 and
45 on host connection index 1.
SN60023 >sfmSparseAccessSet 1,“1,2,3,4,6,9,22,23,45,”1
value=0=0x0
SN60023 >
sfmTypeSet [hostIndex],“OS type string”
The sfmTypeSet command sets the Operating System type for the specified
host connection index. Existing hostindex values can be determined by looking
at the “Id” column in the output of the
sfmShow -1 command. OS must begin
with “NT”, “AIX”, “Linux”, “SOLARIS”, “HP-UX” or “NETWARE”.
Additional information may be appended to these strings as desired.
Choosing “Linux” sets the host type default to “Solaris”.
The following command example shows setting the host type to NT 4.0 SP5 for
host Id 1.
SN60023 > sfmTypeSet 1,"NT 4.0 SP5"
value=0=0x0
SN60023 >
shellLock
Only one management interface may be in use at a time. If a network interface
is opened, Only one management interface may be in use at a time. If a network
Access Meaning
0 Disables access to the LUNs
1 enables access to the LUNs