SNC 5100
164 Commands
6-00020-02
SN60023 > setNettime 1
Nettime 1 value=0=0x0
setSnaCCLun [newLUN]
The
setSnaCCLun command reassigns the SNC 5100's Command and Control
LUN to the specified value.
newLUN is the new value for the Command and Control LUN. Valid values
are 0 through 127.
The new setting takes effect immediately. The previous value is removed from
the device map and database and a trap is generated indicating that the device
was removed.
If the new LUN is not currently in use, a new entry is added in the device map
and database. A trap will be generated indicating the new device was added.
If the new LUN is already in use, the Command and Control LUN will be
disabled. It will remain disabled until the device mapped at the requested LUN
is removed and deleted from the database. In this case, you can use the
mapRebuildDatabase command to remove the previous LUN assignment
and to allow the new Command and Control LUN to be enabled.
Caution
Because AIX and NT use LUN 0 when they issue a Report LUNs
command, you must make sure that a device is configured at LUN
0.
setTimeHost
The
setTimeHost command adds a host running timeserver to the SNC 5100
system. The
setNettime 1 command must already have been issued. To
add a host named Cronos to the system enter the following command:
SN60023 > setTimeHost Cronos
Time Host Cronos value=0=0x0
SN60023 >
sfmAccessApply
The
sfmAccessApply command causes the settings that have been changed
and stored in memory to take effect immediately and also saves them to the
SFM database.