ADIC SNC 5100 Network Card User Manual


 
SNC 5100
122 Commands
6-00020-02
fcConnTypeSet [port],[connection]
The
fcConnTypeSet command is used to set the type of connection for a
Fibre Channel port. See also the
fcConnTypeGet command
The following example shows how to set Fibre Channel port 1 connection type
to point-to-point.
SN60023 > fcConnTypeSet 1,1
value=0=0x0
SN60023 >
Caution
You must issue the fcRestart command or reboot the SNC 5100
for the new setting to take effect. See the
fcRestart command for
further information.
fcFibreSpeedGet [port]
The
fcFibreSpeedGet command displays the requested speed of the Fibre
Channel port. The actual speed can be viewed in the output of the
fcShow
command. The example below shows that Fibre Channel port 1 has a
maximum speed of 1 Gb/sec.
SN60023 > fcFibreSpeedGet 1
value = 1= 0x1
SN60023 >
Parameter Value Meaning
Port 1 The SNC 5100 Connection labeled FC1
2 The SNC 5100 Connection labeled FC2
Connection Type 0 Loop
1 Point-to-Point
2 Loop Preferred
Parameter Value Meaning
port 1 The SNC 5100Connection labeled FC1