ADTRAN 6000 Series Network Card User Manual


 
Section 7 MIBs TRACER 6000 Series Integrated System Manual
112 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F
TRACER6000.mib adTRACERBPVoff a change in the BiPolar Violation (BPV) state has
occurred and the BPV alarm is inactive.
adTRACERRAoff a change in the Frame RA (Remote Alarm) state has
occurred and the RA alarm is inactive.
adTRACEROOFoff a change in the Out Of Frame (OOF) state has
occurred and the OOF alarm is inactive.
adTRACERCVoff a change in the Code Violation (CV) state has
occurred and the CV alarm is inactive.
adTRACERCRCoff a change in the Cyclic Redundancy Check (CRC)
state has occurred and the CRC alarm is inactive.
adTRACERmfLOFoff a change in the Loss of Multiframe (LOMF) state has
occurred and the LOMF alarm is inactive.
adTRACERmfLOSoff a change in the Multiframe Loss of Signal (LOS)
state has occurred and the Multiframe LOS alarm is
inactive.
adTRACERmfAISoff a change in the Multiframe Alarm Indication Signal
(AIS) state has occurred and the Multiframe AIS
alarm is inactive.
adTRACERmfRAoff a change in the Multiframe Remote Alarm (RA) has
occurred and the Multiframe RA alarm is inactive.
adTRACERlineLoopbackOff a change in the line loopback state has occurred and
the line loopback is inactive.
adTRACERlinkLoopbackOff a change in the link loopback state has occurred and
the link loopback is inactive.
adTRACERLinkDown the RF link is down.
adTRACERLinkUp the RF link is up.
adTRACERRFCLinkDown* the RFC link is down between the Indoor Unit (IDU)
and Outdoor Unit (ODU). This trap only applies to
TRACER split systems.
adTRACERRFCLinkUp* the RFC link is up between the IDU and ODU. This
trap only applies to TRACER split systems.
adTRACERRxLow the receive level is within 10 dB of sensitivity and the
RF Low alarm is active.
adTRACERRxLevel a change in receive level has occurred and the
receive level is within normal range.
adTRACERcurrThrsESon the threshold for current Errored Seconds (ES) has
been exceeded.
adTRACERcurrThrsESoff the threshold for current ES has not been exceeded.
adTRACERcurrThrsSESon the threshold for current Severely Errored Seconds
(SES) has been exceeded.
adTRACERcurrThrsSESoff the threshold for current SES has not been
exceeded.
Table 3. Traps Supported by the TRACER 64x0 (Continued)
MIB Trap This trap indicates that....
* Not supported in TRACER 64x0 models. Listed trap only applies to TRACER split systems.