ADTRAN 6000 Series Network Card User Manual


 
Section 3 Engineering Guidelines TRACER 6000 Series Integrated System Manual
42 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F
Mechanical and Environmental
Operating Temperature -25°C to 65°C
Size
1.7 inch (4.4 cm) H
17.2 inch (43.7 cm) W
11.4 inch (28.9 cm) D
Humidity 95 percent, noncondensing
Weight 7 lbs (3.18 kg)
Power
Input Voltage 21 to 60 VDC, either polarity referenced to ground
Power Consumption < 25 W
Connector 2-pin terminal block (DC)
Fuse 2 A, 250 V slow-blo fuse (2-inch)
Network Modules
Quad T1 Module
Connection Four RJ-45 interfaces
Capacity
4xT1 (ANSI T1.403, AT&T
®
54016 and 62411)
Line Code B8ZS (default), AMI
Alarms AIS, Red, Yellow, BPVs, LOS
Quad Ethernet
Switch Module
Connection Four RJ-45 interfaces
Interface Type Four 10BaseT/100BaseTX interfaces with auto MDI/MIDX
crossover
Flow Control Back-pressure flow control on half-duplex interfaces
Pause-frame flow control on full-duplex interfaces
Quad E1 Module
(120 Interface)
Connection Four RJ-45 interfaces
Capacity 4xE1 (CCITT G.703)
Line Code HDB3 (default), AMI
Alarms LOS, LCV, AIS, RMT, OOF, CRC
Loopbacks Local and remote line and link
Quad E1 Module
(75 Interface)
Connection Single DB-25 connector on module; 75 unbalanced interface
available using BNC breakout panel
Capacity 4xE1 (CCITT G.703)
Line Code HDB3 (default), AMI
Alarms LOS, LCV, AIS, RMT, OOF, CRC
Loopbacks Local and remote line and link
Table 15. At-A-Glance Specifications (Continued)
Hardware Description Specification