ADTRAN 6000 Series Network Card User Manual


 
TRACER 6000 Series Integrated System Manual Section 3 Engineering Guidelines
612806420L1-1F Copyright © 2005 ADTRAN, Inc. 41
Frequency Plan
Plan A
Channel Plan
1
Tx 2.419 GHz, Rx 2.459 GHz (TRACER 6410)
Tx 5.744 GHz, Rx 5.824 GHz (TRACER 6420)
2
Tx 2.422 GHz, Rx 2.462 GHz (TRACER 6410)
Tx 5.747 GHz, Rx 5.827 GHz (TRACER 6420)
3
Tx 2.425 GHz, Rx 2.465 GHz (TRACER 6410)
Tx 5.751 GHz, Rx 5.831 GHz (TRACER 6420)
Plan B
Channel Plan
1
Tx 2.459 GHz, Rx 2.419 GHz (TRACER 6410)
Tx 5.824 GHz, Rx 5.744 GHz (TRACER 6420)
2
Tx 2.462 GHz, Rx 2.422 GHz (TRACER 6410)
Tx 5.827 GHz, Rx 5.747 GHz (TRACER 6420)
3
Tx 2.465 GHz, Rx 2.425 GHz (TRACER 6410)
Tx 5.831 GHz, Rx 5.751 GHz (TRACER 6420)
Data Encryption
Encryption Type
Symmetric Triple-DES (3DES)
User Interface
Panel Alarm LEDs
Diagnostics RF link diagnostics and error history, transmit and receive packets
history, real-time signal levels
Test Points RSSI and Ground (GND)
Alarms Normally Open (NO) and Normally Closed (NC)
VT100 Terminal Menu-driven user interface, control of the remote end, event history
Telnet Access Menu-driven user interface, control of the remote end, event history
SNMP Standard MIB support (T1/E1 and Ether-like MIBs); Enterprise MIB
support (ADTRAN TRACER)
VT100 Terminal Interface
Data Rate 9600, 19200, 38400, 57600, 115200 bps
Data Bits 8
Parity None
Stop Bits 1
Terminal Emulation VT100
Table 15. At-A-Glance Specifications (Continued)
Hardware Description Specification