ADTRAN 6000 Series Network Card User Manual


 
Section 6 DLP-1 TRACER 6000 Series Integrated System Manual
92 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F
1. Connecting a VT100 terminal to the TRACER 64x0:
2. Connecting a PC emulating a VT100 terminal to the TRACER 64x0:
Most PCs or laptops can run communications software that emulates a VT100 terminal. Examples
include Windows programs such as Terminal
® or Hyperterminal®. However, there are many other
adequate, commercially available software packages which will allow your PC or laptop to emulate a
VT100 terminal.
You are now ready to log in to the TRACER 64x0 as described in DLP-2, Logging into the TRACER 64x0, on
page 93.
Perform one of the following steps:
Set the parameters of the VT100 terminal or PC to match the default settings on the
TRACER 64x0:
9600 baud rate
8 data bits
No parity
1 stop bit
No flow control
If the terminal has a parallel setting, disable this setting and use the serial port.
Using the CRAFT Port
Plug the DB-9 male end of the data cable into the TRACER 64x0 CRAFT port on the front
of the unit. Make the connection to the VT100 terminal as appropriate for your equipment.
Set the parameters of the communications software to match the default settings on the
TRACER 64x0:
9600 baud rate
8 data bits
No parity
1 stop bit
No flow control
Set the PC for direct connect (instead of dial up connection) on the appropriate com port.
Using the CRAFT Port
Plug the DB-9 male end of the data cable into the TRACER 64x0 CRAFT port on the front
of the unit. Make connection to the PC or laptop as appropriate for your equipment.