ADTRAN 6000 Series Network Card User Manual


 
Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual
62 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F
> SYSTEM CONFIGURATION > CRAFT PORT BAUD
Specifies the baud rate of the port. Select either 9600 (default), 19200, 38400, 57600, or 115200 bps. If
you are using the
CRAFT port for modem access, ensure that the CRAFT port rate matches the modem
baud rate.
> SYSTEM CONFIGURATION > INACTIVITY LOGOUT
This option defines the amount of time in minutes the user can stay connected without any activity on the
CRAFT port before the user is automatically logged out of the system. Select one of the following: 5 MIN,
10 MIN (default), 15 MIN, 30 MIN, 45 MIN, 60 MIN, or OFF.
> SYSTEM CONFIGURATION > PASSWORD
Sets the password for password protection of the TRACER 64x0 terminal interface. Enter up to eight
alphanumeric characters. The system password is case sensitive.
> SYSTEM CONFIGURATION > PERFORMANCE STATS (CLEAR)
Resets all system error counters for the TRACER 64x0.
> SYSTEM CONFIGURATION > FACTORY DEFAULTS
Resets the system to the factory default settings. The configured IP ADDRESS, SUBNET MASK, and DEFAULT
G
ATEWAY are not defaulted during a factory default. When you select this command, the following
confirmation message appears:
Are you sure you want to restore factory Defaults? Y or N
Press
Y to restore factory defaults or N to cancel this command.
Changes to the INACTIVITY LOGOUT setting do not apply to the current session. All changes
take affect at the next login to the system menus.
The default password for the TRACER 64x0 is password.
The TOTAL ACTIVE CHANNELS parameter (on the Datapath Provisioning menu page) is
reset to the factory default value (
8). Performing a factory default on any system with less
than eight active channels results in an RF link loss.