ATEN Technology KN4140V Switch User Manual


 
Appendix
215
4. When you have finished making your selections, click Save.
Operation
To operate the device connected to the port, in the Port Access page double
click the port. After you switch to the port, issue the command that calls up the
device.
KA7140 Pin Assignments
Pin assignments for the KA7140 Adapter are given in the table, below:
Parity This bit checks the integrity of the transmitted data. Choices
are: None; Odd; Even. Set this to match the parity setting of the
serial console device. Default is Odd.
Stop Bits This indicates that a character has been transmitted. Set this to
match the stop bit setting of the serial console device. Choices
are: 1 and 2. Default is 1 (which is the default for the majority of
serial console devices).
Flow Control This allows you to choose how the data flow will be controlled.
Choices are: None, Hardware, and XON/XOFF. Set this to
match the flow control setting of the serial console device.
Default is None.
Note: None is only supported for baud rates of 9600 and lower.
For baud rates greater than 9600, you must choose Hardware
or XON/XOFF.
Access Mode This allows you to set the serial console device’s access mode.
Choices are: Share, Occupy, and Exclusive. Default is Share.
See Access Mode, page 87 for information regarding this
function.
Pin Assignment
1 DCD
DB9 Female
2RXD
3TXD
4DTR
5GND
6DSR
7RTS
8CTS
9N/A
Setting Meaning