Cisco Systems MDS 9200 Series Switch User Manual


 
Send documentation comments to mdsfeedback-doc@cisco.com
B-18
Cisco MDS 9200 Series Hardware Installation Guide
OL-17468-02
Appendix B Technical Specifications
SFP and SFP+ Transceiver Specifications
Table B-32 lists the Cisco 4-Gbps CWDM SFP transceivers available through Cisco.
Environmental and Optical Specifications for Cisco 2-Gbps CWDM SFP Transceivers
Table B-33 provides the environmental specifications for the Cisco 2-Gbps CWDM SFP transceivers.
Table B-34 provides the optical specifications for the Cisco 2-Gbps CWDM SFP transceivers.
Table B-32 Cisco 4-Gbps CWDM SFP Transceivers
Description Color
DS-CWDM4G1470: Cisco MDS9000 1470 nm; CWDM 4-Gbps FC Gray
DS-CWDM4G1490: Cisco MDS9000 1490 nm; CWDM 4-Gbps FC Violet
DS-CWDM4G1510: Cisco MDS9000 1510 nm; CWDM 4-Gbps FC Blue
DS-CWDM4G1530: Cisco MDS9000 1530 nm; CWDM 4-Gbps FC Green
DS-CWDM4G1550: Cisco MDS9000 1550 nm; CWDM 4-Gbps FC Yellow
DS-CWDM4G1570: Cisco MDS9000 1570 nm; CWDM 4-Gbps FC Orange
DS-CWDM4G1590: Cisco MDS9000 1590 nm; CWDM 4-Gbps FC Red
DS-CWDM4G1610: Cisco MDS9000 1610 nm; CWDM 4-Gbps FC Brown
Table B-33 Environmental Specifications for Cisco 2-Gbps CWDM SFP Transceivers
SFP
Operating Storage
Maximum Minimum Maximum Minimum
All Cisco 2-Gbps
CWDM SFP
Transceivers
40°C 0°C 85°C -40°C
Table B-34 Optical Specification for Cisco 2-Gbps CWDM SFP Transceivers
Parameters Symbol Minimum Typical Maximum Units Notes/Conditions
Transmitter Center
Wavelength
λ
c
x-4 x+7 nm Available center
wavelengths are
1470, 1490,
1510, 1530,
1550, 1570,
1590, and 1610
nm
Side-mode
Suppression Ratio
SMSR 30 dB
Transmitter Optical
Output Power
P
out
0.0 5.0 dBm Average power
coupled into
single-mode fiber
Receiver Optical
Input Power (BER
<10-12 with PRBS
2-7-1)
P
in
-28.0 -7.0 dBm At 2.12 Gbps,
140°F (60°C)
case temperature