Cisco Systems MDS 9200 Series Switch User Manual


 
Send documentation comments to mdsfeedback-doc@cisco.com
2-37
Cisco MDS 9200 Series Hardware Installation Guide
OL-17468-02
Chapter 2 Installing the Cisco MDS 9200 Series
Removing and Installing Components
Figure 2-21 845-W AC Power Supply Front Panel
Step 4
Hold the power supply by the handle and orient it as shown in Figure 2-22, and then slide it into the
power supply bay, ensuring that it is fully seated in the bay.
Figure 2-22 Handling an 845-W AC Power Supply
Step 5
Tighten the power supply captive screws.
Step 6 Plug the power cable into the power supply, and tighten the screw on the power cable retainer to ensure
the cable cannot be pulled out.
Note Depending on the outlet receptacle on your power distribution unit, you may need the optional
jumper power cord to connect the Cisco MDS 9200 Series to your outlet receptacle. See the
“Jumper Power Cord” section on page C-11.
Step 7 Connect the other end of the power cable to an AC power source.
1 Power switch 4 AC power connection
2 Power cable retainer 5 Captive screw
3 Power supply LEDs
94976
PWR-845-AC
100-240V 12-5A
50/60 Hz
INPUT OK
FAN OK
OUTPUT FAIL
ALL FASTENERS MUST BE FULLY ENGAGED
PRIOR TO OPERATING OF POWER SUPPLY
5
1
2 3
4
94975