Cisco Systems MDS 9200 Series Switch User Manual


 
Send documentation comments to mdsfeedback-doc@cisco.com
2-31
Cisco MDS 9200 Series Hardware Installation Guide
OL-17468-02
Chapter 2 Installing the Cisco MDS 9200 Series
Removing and Installing Components
Figure 2-19 Clearing the EMI Gasket
Removing a Caching Services Module
Note A minimum of two CSMs in each fabric are required for redundancy and data backup.
Warning
Do not touch or bridge the metal contacts on the battery. Unintentional discharge of the batteries can
cause serious burns.
Statement 341
Warning
Ultimate disposal of this product should be handled according to all national laws and regulations.
Statement 1040
Caution Wait for all LEDs to turn off before removing the module from the chassis. If the LEDs are on, the
module still has power.
M
DS 9216i
G
E
1
L
I
N
K
G
E
2
L
I
N
K
5
6
7
8
9
1
0
11
12
13
1
4
1
2
3
4
122001
1mm
Amount of gap
between the
module EMI
gasket and the
module above it
2
1
Press down
Press down
STATUS