Dell FCX624-E Laptop User Manual


  Open as PDF
of 1494
 
376 PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Virtual Switch Redundancy Protocol (VSRP)
10
VSRP-aware interoperablilty
The vsrp-aware tc-vlan-flush command should be used in network configurations in which the Dell
PowerConnect switch operates as the VSRP-Aware device connecting to a other devices as a VSRP
Master.
The command is available at the VLAN level, and is issued per a specific VRID, as shown here for
VRID 11.
PowerConnect(config-vlan-10)#vsrp-aware vrid 11 tc-vlan-flush
Syntax: vsrp-aware vrid <num> tc-vlan-flush
When this command is enabled, MAC addresses will be flushed at the VLAN level, instead of at the
port level. MAC addresses will be flushed for every topology change (TC) received on the
VSRP-aware ports.
When this command is enabled, the results of the show vsrp-aware vlan command resemble the
following.
PowerConnect(config-vlan-10)#vsrp-aware vrid 11 tc-vlan-flush
PowerConnect(config-vlan-10)#show vsrp aware vlan 10
Aware Port Listing
VLAN ID VRID Last Port Auth Type Mac-Flush Age
10 11 N/A no-auth Configured Enabled 00:00:00.0
Displaying VSRP information
You can display the following VSRP information:
Configuration information and current parameter values for a VRID or VLAN
The interfaces on a VSRP-aware device that are active for the VRID
Displaying VRID information
To display VSRP information, enter the following command.
Syntax: show vsrp [vrid <num> | vlan <vlan-id>]
PowerConnect#show vsrp vrid 1
Total number of VSRP routers defined: 2
VLAN 200
auth-type no authentication
VRID 1
State Administrative-status Advertise-backup Preempt-mode save-current
standby enabled disabled true false
Parameter Configured Current Unit
priority 100 80 (100-0)*(4.0/5.0)
hello-interval 1 1 sec/1
dead-interval 3 3 sec/1
hold-interval 3 3 sec/1
initial-ttl 2 2 hops
next hello sent in 00:00:00.8
Member ports: ethe 1/1 to 1/5
Operational ports: ethe 1/1 to 1/4
Forwarding ports: ethe 1/1 to 1/4