Dell NX200 Personal Computer User Manual


 
24 About Your System
NOTE: The following LCD status messages are displayed in the Simple format.
Table 1-1. LCD Status Messages
Code Text Causes Corrective Actions
E1000 Failsafe
voltage
error.
Contact
support.
Check the system event log
for critical failure events.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 157.
E1114 Ambient Temp
exceeds
allowed
range.
Ambient temperature has
reached a point outside of
the allowed range.
See "Troubleshooting
System Cooling Problems"
on page 136.
E1116 Memory
disabled,
temp above
range. Power
cycle AC.
Memory has exceeded
allowable temperature
and has been disabled
to prevent damage to
the components.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
System Cooling Problems"
on page 136. If the problem
persists, see "Getting Help"
on page 157.
E1210 Motherboard
battery
failure.
Check
battery.
CMOS battery is missing
or the voltage is outside
of the allowable range.
See "Troubleshooting the
System Battery" on
page 134.
E1216 3.3V
Regulator
failure.
Reseat PCIe
cards.
3.3V voltage regulator
has failed.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 143.
book.book Page 24 Monday, August 9, 2010 3:07 PM