Dell NX200 Personal Computer User Manual


 
About Your System 31
E2011 Memory
configuratio
n failure.
Check DIMMs.
Memory detected, but is
not configurable.
Error detected during
memory configuration.
See "Troubleshooting
System Memory" on
page 137.
E2012 Memory
configured
but unusable.
Check DIMMs.
Memory configured,
but is unusable.
See "Troubleshooting
System Memory" on
page 137.
E2013 BIOS unable
to shadow
memory. Check
DIMMs.
The system BIOS failed
to copy its flash image
into memory.
See "Troubleshooting
System Memory" on
page 137.
E2014 CMOS RAM
failure.
Power cycle
AC.
CMOS failure.
CMOS RAM not
functioning properly.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 157.
E2015 DMA
Controller
failure.
Power cycle
AC.
DMA controller failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 157.
E2016 Interrupt
Controller
failure.
Power cycle
AC.
Interrupt controller failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on
page 157.
Table 1-1. LCD Status Messages
(continued)
Code Text Causes Corrective Actions
book.book Page 31 Monday, August 9, 2010 3:07 PM