Dell NX200 Personal Computer User Manual


 
34 About Your System
E2023 BIOS unable
to mirror
memory. Check
DIMMs.
The system BIOS could
not enable memory
mirroring because of a
faulty memory module or
an invalid memory
configuration.
See "Troubleshooting
System Memory" on
page 137.
E2110 Multibit
Error on DIMM
##. Reseat
DIMM.
The memory module in
slot "##" has had a multi-
bit error (MBE).
See "Troubleshooting
System Memory" on
page 137.
E2111 SBE log
disabled on
DIMM ##.
Reseat DIMM.
The system BIOS has
disabled memory single-bit
error (SBE) logging and
will not log any more SBEs
until the system is
rebooted. "##" represents
the memory module
implicated by the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 137.
E2113 Mem mirror
OFF on DIMM
## & ##.
Power cycle
AC.
The system BIOS has
disabled memory mirroring
because it has determined
one half of the mirror has
had too many errors. "##
& ##" represents the
memory module pair
implicated by the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 137.
I1910 Intrusion
detected.
Check chassis
cover.
System cover has been
removed.
Information only.
Table 1-1. LCD Status Messages
(continued)
Code Text Causes Corrective Actions
book.book Page 34 Monday, August 9, 2010 3:07 PM