Delta Electronics VFD-F Series Network Card User Manual


 
8
VFD-F Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
8-1
CHAPTER 8 PARAMETER SUMMARY
Group 0 AC Drive Status Parameter
Parameters Functions Settings
Factory
Setting
Customer
00-00 Software Version Read only
00-01 AC Drive Status Indication 1 00: No Fault occurred
01: oc (over current)
02: ov (over voltage)
03: oH (over temperature)
04: oL (overload)
05: oL1 (electronic thermal relay)
06: EF (External Fault)
07: occ (AC drive IGBT fault)
08: cF3 (CPU failure)
09: HPF (Hardware Protection
Failure)
10: ocA (current exceed during
Acceleration)
11: ocd (current exceed during
Deceleration)
12: ocn (current exceed during
Steady State)
13: GFF (Ground Fault)
14: Lv (Low voltage)
15: cF1 (input data abnormal)
16: cF2 (output data abnormal)
17: bb (base block)
18: oL2 (over load2)
19: Reserved
20: codE (software or password
protection)
21: EF1 (external emergency stop)
22: PHL (phase loss)
23: Lc (Low current)
24: FbL (Feedback loss)
25: Reserved
26: FAnP (Fan Power Fault)
27: FF1 (Fan 1 fault)
28: FF2 (Fan 2 fault)
29: FF3 (Fan 3 fault)
30: FF123 (Fan 1, 2, 3 fault)
31: FF12 (Fan 1, 2 fault)
32: FF13 (Fan 1, 3 fault)
33: FF23 (Fan 2, 3 fault)
34: Fv (Gate Drive Low Voltage
Protect)
Read