The information is described as follows:
Time Interval
Select the desired setting between 1s and 60s, where “s” stands for
seconds. The default value is one second.
Record Number
Select number of times the Switch will be polled between 20 and 200.
The default value is 20.
ExDefer
Counts the number of frames for which the first transmission attempt
on a particular interface was delayed because the medium was busy.
CRCError
Counts otherwise valid frames that did not end on a byte (octet)
boundary.
LateColl
Counts the number of times that a collision is detected later than 512
bit-times into the transmission of a packet.
Show/Hide
Check whether or not to display ExDefer, CrcError, and LateColl
errors.
Clear
Clicking this button clears all statistics counters on this window.
View Table
Clicking this button instructs the Switch to display a table rather than a
line graph.
View Line Chart
Clicking this button instructs the Switch to display a line graph rather
than a table.
Size
The Web Manager allows packets received by the Switch, arranged in six groups, to be viewed as either a line
graph or a table. The two windows offered are as follows:
Packet Size