CHAPTER 4 Installation of Operating System and bundled software
4.2 Procedure to install Windows in SAN/iSCSI storage device
50
- When Qlogic Converge Console (GUI/CLI) is not installed
The installation condition of Qlogic Converge Console (GUI) is determined by the presence of [Qlogic Corporation] –
[QCC GUI (localhost)] under the [start] menu – [all programs]
The installation condition of Qlogic Converge Console (CLI) is determined by the presence of [Qlogic Management
Suite] -[QConvergeConsole CLI] under the [start] menu – [all programs]
Note
In Windows Server 2012 or Windows Server 2012 R2, “the [start] menu – [all programs]“ should read “the [start]
menu – [all apps]“.
a. Driver/ Utility ofMC-0JFC5X or MC-0JFC6X is downloaded from the following URL.
http://support.ts.fujitsu.com/
Note
Driver/Utility can be used by the PRIMEQUEST 2000 series though PRIMERGY is described in the
downloaded binary.
b. The downloaded file is executed by a double click.
The prompt window of cmd.exe (black window) is displayed for a while and the file is extracted.
c. The window closes automatically after the extraction is completed.
The download file is extracted and folder or file is newly created.
Remark
If the window does not close even if "Complete" is displayed on the title bar of the window then click the "Close"
button and close the window.
d. Double click and execute "QConvergeConsole_Installer_Windows_XXXXX.exe" in "QCC_vXXXXXX" directory
created by extraction.
Remark
"XXXX" shows the version number. Read properly.
3. When the installation is completed, the partition is rebooted.
4. The setting of management is confirmed.
Confirm STP function for switch is turned off if the switch is connected to management LAN for MMB.
5. The trap destination and mail destination are set through MMB.
Execute the coordination with the management software, etc. only if necessary.
a. [SNMP settings] is displayed on the MMB window and enable [SNMP] .
b. The trap destination of SNMP through MMB is set.
“6.5.2 Set up of SNMP”
6. Dump area is set.
Confirm that there is sufficient free space on the hard disk before acquiring the memory damp.
For details, see "11.4.3 Settings of dump environment (Windows)" of PRIMEQUEST 2000 series Administration
Manual (C122-E175EN).
7. The management information and configuration information are stored.
For details, see “5.7 Saving management and configuration information”.
8. RAS support service is set.
For details, see “5.8 Setup for lifespan monitoring according to RAS support service”.
- When the duration of life of the UPS battery is monitored: see “5.8.1 Monitoring life-span of UPS battery”
9. Watchdog Timer allows reboot OS in case that OS freezes. Rebooting OS is executed when the set time
passes,
For details, see “8.4 Automatic Partition Restart Conditions” of PRIMEQUEST 2000 series Administration
Manual (C122-E175EN).
4.2.5 Connection of SAN and the internal HDD/SDD after installation
For SAN and the internal HDD/SDD connection after the completion of installation, see PRIMEQUEST 1000/2000 Series
SAN Boot Environment Configuration Manual (C122-E155) .
1. Change and confirm the settings of the detailed information of the FC card.
For details, see PRIMEQUEST 1000/2000 Series SAN Boot Environment Configuration Manual (C122-E155).
2. OneCommand Manager is started. The following driver parameters are set.
For the details of the set value, see San storage device manual.
- Topology
- Queue Depth
- Queue Target
- Link Speed
3. Check the registry information.
For details on the checking method, see PRIMEQUEST 1000/2000 Series SAN Boot Environment Creation Manual
(C122-E155).