CHAPTER 4 Installation of Operating System and bundled software
4.10 Procedure to install SUSE Linux Enterprise Server 11 Service Pack 3 into the SAN Storage Unit
66
4.10 Procedure to install SUSE Linux Enterprise Server 11
Service Pack 3 into the SAN Storage Unit
This section describes the procedures for installing SUSE Linux Enterprise Server 11 Service Pack 3 (referred to below as
SLES11 SP#) on the SAN storage unit. Confirm the MMB configuration and successful login to the MMB before starting
the installation.
For details on configuring the SAN storage unit and FC card , Converged Network Adapter and NIC for iSCSI Boot , see
the PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual (C122-E155EN).
4.10.1 Presetting
Set the following if necessary.
1. Set the LUN of the SAN storage device.
2. [PCI ROM Priority] of BIOS is set.
- For the UEFI Install
- Set [Device Manager]-[PCI Subsystem Configuration]-[PCI ROM Priority] of BIOS menu to ”EFI Compatible
ROM”.
- For the UEFI Install:
- Set [Device Manager]-[PCI Subsystem Configuration]-[PCI ROM Priority] of BIOS menu to ”Legacy ROM”.
- Set [Device Manager]-[PCI Subsystem Configuration]-[OpROM Scan Configuration] of BIOS menu to “Enable”
only for booting Device.
3. Set the BIOS to recognize LUN of the FC card, Converged Network Adapter and NIC for iSCSI Boot.
For setting the FC card, Converged Network Adapter and NIC for iSCSI Boot, see PRIMEQUEST 1000/2000 Series
SAN Boot Environment Configuration Manual (C122-E155).
4. Prepare the server that operates ServerView Operations Manager (SVOM).
5. Check the setting of the partition by MMB after removing the internal HDD/SSD of PRIMEQUEST.
- SB/IOU configuration is set
See “3.4.1 Setting the partition configuration”
- Console redirection is set
See “3.4.6 Settings of Console Redirection”
- Video redirection: Enable
- Virtual media: Enable
- Various modes are set
See “3.4.5 Various mode settings”
6. Connect only the LUN which installs the SAN storage device to the partition of PRIMEQUEST.
For the setting of SAN storage device, see the manual attached with the SAN storage device.
7. Allocate the I/O space in the FC card for boot path and in the SAS RAID controllerRAID card.
For details on allocation of the I/O space, see “3.4.5 Various mode settings” and “5.5.1 [Configure I/O Space
Assignment] menu” of PRIMEQUEST 2000 Series Tool Reference (C122-E177EN).
4.10.2 Preparation of installation
Prepare the SLES11 SP3 installation DVD.
Preparation for boot
The FC cable is made single path (connect only one FC cable).
4.10.3 Installation
The operating system installation with SVIM is explained.