Fujitsu F2 MC-16 Computer Accessories User Manual


 
90
CHAPTER 2 DEPENDENCE FUNCTIONS
2.2.6.1 Operation in Normal Mode
As shown in the figure below, the event trigger set in the normal mode performs input to
the sequencer. In the sequencer, either branching to any level, or terminating the
sequencer, can be specified as an operation at event trigger occurrence. This enables
debugging (breaks, limiting trace, measuring time) while monitoring program flow.
Operation in Normal Mode
The termination of sequencer triggers the delay counter. When the delay counter reaches the specified count,
sampling for the single trace terminates. A break normally occurs at this point, but if necessary, the program
can be allowed to run on without a break.
Figure 2.2-3 Operation in Normal Mode
Events
SET EVENT
CANCEL EVENT
SHOW TRACE/STATUS
SHOW DELAY
DISABLE EVENT
ENABLE EVENT
SHOW EVENT
SHOW SEQUENCE level
SET
SEQUENCE/EVENT
CANCEL
SEQUENCE/EVENT
SHOW SEQUENCE/ALL
SET DELAY
SET
SEQUENCE/TIMER
CANCEL
SEQUENCE/TIMER
SET SEQUENCE/DISABLE TRACE
SET SEQUENCE/ENABLE TRACE
SET SEQUENCE/NO TRACE
CLEAR TRACE
SEARCH TRACE
SHOW TRACE/DATA
ENABLE TRACE
DISABLE TRACE
SET TRACE
Enable/Disable
control
Enable
Disable
Select event number causing
trigger at each level, set
pass count value.
Timer setup
for each
condition
When each condition at each level met
When condition met
Delay
counter
Sequencer
Timer latch
When count ends
When count ends
Instructing MCU to
suspend operation
Buffer-full break
control
Single trace measurement
Enable/Disable
control
Measurement ends